Backbone City Network System

Dielectric Loose Tube for Pulled-in Installation Technique

Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, peripheral strength  elements of aramid or glass, PE outer sheath.

 B3
P/N
 No. of
Fibres

 No.
Tubes

 No. Fibres
Per Tube

 Cable
Diameter
(mm)

 Min Bend
Radius
(mm)

 E-012-SM2-L12-D-W-PKP
 12  1  12  12.5  187.5
 E-024-SM2-L12-D-W-PKP
 24  2  12  12.5  187.5
 E-048-SM2-L12-D-W-PKP
 48  4  12  12.5  187.5
 E-096-SM2-L12-D-W-PKP
 96  8  12  17.0  255.0
 E-144-SM2-L12-D-W-PKP
 144  12  12  20.0  300.0

Please note: The above cables are available in the range 12 - 256 fibres
The cables are also available in LS-HFFR version, with an external sheath of
Low Smoke Flame Retardant outer sheath: I-012-SM2-L12-D-W-KT
The cables are also available in double sheath construction version:
E-012-SM2-L12-D-W-PKP The cables have been tested to show compliance with
European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values,
513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration.



Dielectric Loose Tube for Short-span Aerial Installation Technique

Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath peripheral strength elements of aramid or glass, PE outer sheath.

 B3
P/N
 No. of
Fibres

 No.
Tubes

 No. Fibres
Per Tube

 Cable
Diameter
(mm)

 Min Bend
Radius
(mm)

 A-012-SM2-L12-D-W-PKP
 12  1  12  14.5  217.5
 A-024-SM2-L12-D-W-PKP
 24  2  12  14.5  187.5
 A-048-SM2-L12-D-W-PKP
 48  4  12  14.5  187.5
 A-096-SM2-L12-D-W-PKP
 96  8  12  19.0  255.0
 A-144-SM2-L12-D-W-PKP
 144  12  12  22.0  300.0

Please note: The above cables are available in the range 12 - 256 fibres. They
have been tested to show compliance with European Norm (EU) 187000.
501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature
Cycling, and 605B - Water Penetration.



ADSS Cable - All Dielectric Self-Supporting Cable

Dielectric strength member, gel filled loose tubes with 2 - 12 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath, peripheral strength elements of aramid, PE outer sheath.

 B3
P/N
 No. of
Fibres

 No.
Tubes

 No. Fibres
Per Tube

 Cable
Diameter
(mm)

 Min Bend
Radius
(mm)

 A-012-SM2-L12-D-W-PKP
 12  1  12  14.0  210.0
 A-024-SM2-L12-D-W-PKP
 24  2  12  14.0  210.0
 A-048-SM2-L12-D-W-PKP
 48  4  12  14.0  210.0
 A-096-SM2-L12-D-W-PKP
 96  8  12  19.0  285.0
 A-144-SM2-L12-D-W-PKP
 144  12  12  24.0  350.0

Please note: The above cables are available in the range 8 - 256 fibres.
The cables have been tested to show compliance with European Norm (EU)
187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend,
601 - Temperature Cycling, and 605B - Water Penetration.



Dielectric Loose Tube

Dielectric strength member, gel filled loose tubes with 2 - 16 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath optional), peripheral strength elements of aramid or glass, PE outer sheath.

 B3
P/N
 No. of
Fibres

 No.
Tubes

 No. Fibres
Per Tube

 Cable
Diameter
(mm)

 Min Bend
Radius
(mm)

 E-012-SM2-L12-D-W-PKSP
 12  1  12  12.5  187.5
 E-024-SM2-L12-D-W-PKSP
 24  2  12  12.5  187.5
 E-048-SM2-L12-D-W-PKSP
 48  4  12  12.5  187.5
 E-096-SM2-L12-D-W-PKSP
 96  8  12  17.0  255.0
 E-144-SM2-L12-D-W-PKSP
 144  12  12  20.0  300.0

Please note: The above cables are available in the range 8 - 256 fibres, with a
double sheath option. The cables are also available in LS-HFFR version, with an
external sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-L12-
D-W-TKT. The cables have been tested to show compliance with European Norm
(EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 -
Temperature Cycling, and 605B - Water Penetration.



Dielectric Loose Tube

Dielectric strength member, gel filled loose tubes with 2 - 16 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), laminated steel tape, PE outer sheath.

 B3
P/N
 No. of
Fibres

 No.
Tubes

 No. Fibres
Per Tube

 Cable
Diameter
(mm)

 Min Bend
Radius
(mm)

 E-016-SM2-L04-D-W-PKSP
 16  4  4  14.5  220.0
 E-032-SM2-L08-D-W-PKSP
 32  4  8  14.5  220.0
 E-048-SM2-L08-D-W-PKSP
 48  6  8  14.5  220.0
 E-096-SM2-L12-D-W-PKSP
 96  8  12  16.5  250.0
 E-192-SM2-L16-D-W-PKSP
 192  12  16  21.5  400.0

Please note: The above cables are available in the range 8 - 256 fibres, with a
double sheath option. The cables are also available in LS-HFFR version, with an
external sheath of Low Smoke Flame Retardant outer sheath: I-016-SM2-L04-
D-W-TST. The cables have been tested to show compliance with European Norm
(EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 -
Temperature Cycling, and 605B - Water Penetration.