Dielectric Loose Tube for Blown Installation Technique
Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass (optional), PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-012-SM2-L12-D-W-P
|
12 |
1 |
12 |
9.5 |
114.0 |
E-024-SM2-L12-D-W-P
|
24 |
2 |
12 |
9.5 |
114.0 |
E-048-SM2-L12-D-W-P
|
48 |
4 |
12 |
9.5 |
114.0 |
E-096-SM2-L12-D-W-P
|
96 |
8 |
12 |
11.0 |
132.0 |
E-144-SM2-L12-D-W-P
|
144 |
12 |
12 |
13.6 |
163.2 |
Please note: The above cables are available in the range 12 - 256 fibres
The cables are also available in LS-HFFR version, with an external sheath of Low
Smoke Flame Retardant outer sheath: I-012-SM2-L12-D-W-T. The cables have
been tested to show compliance with European Norm (EU) 187000. 501 - Max
Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and
605B - Water Penetration.
Dielectric Anti-rodent Protected Loose Tube
Dielectric strength member, gel filled loose tubes with 2 - 16 singlemode fibres per tube (G652), fillers where required for cable geometry, water swellable elements of tapes or yarns, HFFR inner sheath (optional), peripheral strength elements of aramid or glass, HFFR outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
C-016-SM2-L04-D-W-TET
|
16 |
4 |
4 |
13.0 |
114.0 |
C-032-SM2-L08-D-W-TET
|
32 |
4 |
8 |
13.0 |
114.0 |
C-048-SM2-L08-D-W-TET
|
48 |
6 |
8 |
13.0 |
114.0 |
C-096-SM2-L12-D-W-TET
|
96 |
8 |
12 |
15.0 |
132.0 |
C-192-SM2-L16-D-W-TET
|
192 |
12 |
16 |
12.0 |
163.2 |
Please note: The above cables are available in the range 8 - 256 fibres, with
a double sheath option. The cables are also available in PE version, with an
external sheath of PE outer sheath: E-016-SM2-L04-D-W-PEP. The cables have
been tested to show compliance with European Norm (EU) 187000. 501 - Max
Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and
605B - Water Penetration.
Metallic Loose Tube with Anti-rodent Protection
Dielectric strength member, gel filled loose tubes with 2 - 16 singlemode fibres per tube (G652), fillers where required for cable geometry, water swellable elements of tapes or yarns, HFFR inner sheath (optional), laminated steel tape, HFFR outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-016-SM2-L04-D-W-PKSP
|
16 |
4 |
4 |
14.5 |
260.0 |
E-032-SM2-L08-D-W-PKSP
|
32 |
4 |
8 |
14.5 |
260.0 |
E-048-SM2-L08-D-W-PKSP
|
48 |
6 |
8 |
14.5 |
260.0 |
E-096-SM2-L12-D-W-PKSP
|
96 |
8 |
12 |
16.5 |
360.0 |
E-192-SM2-L16-D-W-PKSP
|
192 |
12 |
16 |
21.0 |
420.0 |
Please note: The above cables are available in the range 8 - 256 fibres, with
a double sheath option. The cables are also available in PE version, with an
external sheath of PE outer sheath: E-016-SM2-LO4-D-W-PSP. The cables have
been tested to show compliance with European Norm (EU) 187000. 501 - Max
Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and
605B - Water Penetration.
Aerial Figure 8 Metallic Loose Tube Cable
Dielectric strength member, gel filled loose tubes with 2 - 12 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), laminated aluminium copolymer tape, metallic messenger (fi g 8) and PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
A-012-SM2-L12-D-W-AP8
|
12 |
1 |
12 |
12.5 |
210.0 |
A-024-SM2-L12-D-W-AP8
|
24 |
2 |
12 |
12.5 |
210.0 |
A-048-SM2-L12-D-W-AP8
|
48 |
4 |
12 |
12.5 |
210.0 |
A-072-SM2-L12-D-W-AP8
|
72 |
6 |
12 |
12.5 |
210.0
|
Please note: The above cables are available in the range 12 - 144 fibres.
Cables are also available in a double sheath configuration. The cables have been tested to show
compliance with European Norm (EU) 187000. The cables have been tested to show compliance
with European Norm (EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend,
601 - Temperature Cycling, and 605B - Water Penetration.
Aerial Short-span Dielectric Loose Tube Cable - Shot Gun Protected
Dielectric strength member, gel filled loose tubes with 2 - 16 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), peripheral strength elements of aramid, shot-gun protection tape, PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
A-012-SM2-L12-D-W-PKCP
|
12 |
1 |
12 |
15.0 |
210.0 |
A-024-SM2-L12-D-W-PKCP
|
24 |
2 |
12 |
15.0 |
210.0 |
A-048-SM2-L12-D-W-PKCP
|
48 |
4 |
12 |
15.0 |
210.0 |
A-072-SM2-L12-D-W-PKCP
|
72 |
6 |
12 |
15.0 |
210.0 |
Metallic Loose Tube with Anti-rodent Resistance
Dielectric strength member, gel filled loose tube with 2 - 16 singlemode fibres per tube (G652), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), peripheral strength elements of aramid, laminated steel tape, PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-016-SM2-L04-D-W-PKSP
|
16 |
4 |
4 |
14.5 |
260.0 |
E-032-SM2-L08-D-W-PKSP
|
32 |
4 |
8 |
14.5 |
260.0 |
E-048-SM2-L08-D-W-PKSP
|
48 |
6 |
8 |
14.5 |
260.0 |
E-096-SM2-L08-D-W-PKSP
|
96 |
12 |
8 |
18.5 |
360.0 |
E-192-SM2-L16-D-W-PKSP
|
192 |
12 |
16 |
21.5 |
420.0 |
Please note: The above cables are available in the range 8 - 256 fibres, with
a double sheath option. The cables are also available in HFFR version, with an
internal sheath of HFFR outer sheath: I-016-SM2-L04-D-W-KTST. The cables
have been tested to show compliance with European Norm (EU) 187000.501 -
Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling,
and 605B - Water Penetration.
Monotube Dielectric Cable
Dielectric strength member, gel filled loose tube with up to 24 fibres per tube (G652 or G657), or multimode fibres (G651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass, Hydrocarbon-resistant sheathing compound.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-004-SM2-C04-D-W-EP
|
4 |
1 |
4 |
7.2 |
72.0 |
E-008-SM2-C08-D-W-EP
|
8 |
1 |
8 |
7.2 |
72.0 |
E-012-SM2-C12-D-W-EP
|
12 |
1 |
12 |
7.2 |
72.0 |
E-016-SM2-C16-D-W-EP
|
16 |
1 |
16 |
7.2 |
72.0 |
E-024-SM2-C24-D-W-EP
|
24 |
1 |
24 |
7.2 |
72.0 |
Please note: The cables are also available in LS-HFFR version, with an external
sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-C12-D-W-ET
The cables have been tested to show compliance with European Norm (EU)
187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 -
Temperature Cycling, and 605B - Water Penetration.
Monotube Armoured Cable
Dielectric strength member, gel filled loose tube with up to 24 fibres per tube (G652 or G657), or multimode fibres (G651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripheral strength elements of aramid or glass, PE inner sheath (optional), Laminated steel tape, PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-004-SM2-C04-D-W-KPSP
|
4 |
1 |
4 |
9.2 |
185.0 |
E-008-SM2-C08-D-W-KPSP
|
8 |
1 |
8 |
9.2 |
185.0 |
E-012-SM2-C12-D-W-KPSP
|
12 |
1 |
12 |
9.2 |
185.0 |
E-016-SM2-C16-D-W-KPSP
|
16 |
1 |
16 |
9.2 |
185.0 |
E-024-SM2-C24-D-W-KPSP
|
24 |
1 |
24 |
9.2 |
185.0 |
Please note: The cables are also available in LS-HFFR version, with an external
sheath of Low Smoke Flame Retardant outer sheath: I-012-SM2-C12-D-W-VTST
The cables are also available in Hydrocarbon-resistant sheathing compound, with
an external sheath of hydrocarbon-resistant outer sheath: I-012-SM2-C12-D-WVPSPD.
The cables have been tested to show compliance with European Norm
(EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 -
Temperature Cycling, and 605B - Water Penetration.
Metallic Loose Tube
Dielectric strength member, gel filled loose tube with 2 - 16 singlemode fibres per tube (G652 or G655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath (optional), laminated steel tape, PE outer sheath.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
|
E-004-SM2-C04-D-W-ESP
|
4 |
1 |
4 |
7.7 |
77.0 |
E-008-SM2-C08-D-W-ESP
|
8 |
1 |
8 |
7.7 |
77.0 |
E-012-SM2-C12-D-W-ESP
|
12 |
1 |
12 |
7.7 |
77.0 |
E-016-SM2-C16-D-W-ESP
|
16 |
1 |
16 |
7.7 |
77.0 |
E-024-SM2-C24-D-W-ESP
|
24 |
1 |
24 |
7.7 |
77.0 |
Please note: The above cables are available in the range 8 - 256 fibres, with a
double sheath option.
The cables are also available in LS-HFFR version, with an external sheath of Low
Smoke Flame Retardant outer sheath: I-016-SM2-L04-D-W-TST.
The cables are also available in Hydrocarbon-resistant sheathing compound, with
an external sheath of hydrocarbon-resistant outer sheath: I-016-SM2-L04-DW-
PSPD. The cables have been tested to show compliance with European Norm
(EU) 187000. 501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 -
Temperature Cycling, and 605B - Water Penetration.
Microcables Multitube
Microcable 24-144 fibres. Dielectric Loose Tube Microcable for Air blown installation technique. Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G652), fillers where required for cable geometry, PE outer sheath, nylon optional.
B3
P/N |
No. of
Fibres
|
No.
Tubes
|
No. Fibres
Per Tube
|
No.
Fillers
(mm)
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
Dynamic
|
Min Bend
Radius
(mm)
Static
|
30-1024-118-0
|
24 |
2 |
12 |
2 |
5.0 |
100 |
50 |
30-1036-129-0
|
36 |
3 |
12 |
1 |
5.0 |
100 |
50 |
30-1048-119-0
|
48 |
4 |
12 |
0 |
5.0 |
100 |
50 |
30-1064-130-0
|
64 |
5 |
12 |
1 |
5.9 |
118 |
59 |
30-1072-120-0
|
72 |
6 |
12 |
0 |
5.9 |
118 |
59 |
30-1096-121-0
|
96 |
8 |
12 |
0 |
7.0 |
140 |
70 |
30-1144-122-0
|
144 |
12 |
12 |
0 |
9.2 |
184 |
92 |
Please note: The above cable is available in the range 24 - 144 fibres.
Cables are also available with optional Nylon Sheath.The cables have been
tested to show compliance with European Norm (EU) 187000. 501 - Max
Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and
605B - Water Penetration
Microcable Monotube
Monotube Dielectric Microcable for Air Blown installation technique. Dielectric strength member, gel filled loose tube with 2 to 24 singlemode fibres per tube (G652 or G657), or multimode fibres (G651 - OM1, OM2 or OM3), peripheral strength elements of aramid or glass, PE outer sheath, nylon optional.
B3
P/N |
No. of
Fibres
|
Fibre Type
|
Cable
Diameter
(mm)
|
Min Bend
Radius
(mm)
Dynamic
|
Min Bend
Radius
(mm)
Static
|
30-1002-108-0
|
2 |
G652D 9/125μm |
3.0 |
60 |
30 |
30-1004-109-0
|
4 |
G652D 9/125μm |
3.2 |
64 |
32 |
30-1008-110-0
|
8 |
G652D 9/125μm |
3.2 |
64 |
32 |
30-1012-111-0
|
12 |
G652D 9/125μm |
3.2 |
64 |
32 |
30-1016-128-0
|
16 |
G652D 9/125μm |
4.0 |
80 |
40 |
30-1024-112-0
|
24 |
G652D 9/125μm |
4.2 |
84 |
42 |
Please note: The above cable is available in the range 2 to 24 fibres with
Singlemode and Multimode options. Cables are also available with optional
Nylon Sheath.The cables have been tested to show compliance with European
Norm (EU) 187000. 501 - Max. Tensile Load, 504 - Crush Values, 513 - Bend,
601 - Temperature Cycling, and 605B - Water Penetration.